Description
The Fieldpiece Instruments FPI-8111-000 , model DRX3, is an ATEX-rated refrigerant leak detector with a heated diode sensor. The device has been developed for detecting refrigerant leaks and is designed for use with A1, A2L, and A3 refrigerants.
Sensitive detection of coolant leaks
The detector has a stated sensitivity of 1 gram per year. Thanks to the heated diode sensor, leaks of suitable coolants can be detected. The sensitivity is adjustable to high, medium, and low. The detector supports automatic and manual recalibration.
Job Link connectivity
The FPI-8111-000 features a Job Link connection that allows measurement data to be viewed. This supports the user in performing and assessing leak detection work.
Robust housing
The compact, robust housing has protection class IP54. The ATEX classification makes this model suitable for applications where the relevant explosion-proof classification is required. Always check whether the classification matches the specific working environment and the applicable safety regulations.
With its heated diode sensor, adjustable sensitivity, and wireless connectivity, the FPI-8111-000 is a practical solution for refrigeration technicians who want to detect refrigerant leaks in installations with suitable A1, A2L, and A3 refrigerants.
The product description is based on the product information from Linum Europe and the additional specifications from the manufacturer.
Specifications
-
Product type: Refrigerant leak detector
-
Type number: FPI-8111-000
-
Model type: DRX3
-
Brand: Fieldpiece Instruments
-
Sensor type: Heated diode
-
Sensor lifespan: 300 hours under normal use
-
Sensitivity levels: High, medium , and low
-
Detection sensitivity: 1 g/year at rest; 3 g/year in motion
-
Detectable refrigerants: HC, HFC, HCFC, CFC, HFO, mixtures and H₂/N₂ tracer gas
-
Suitable refrigerant classes: A1, A2L and A3
-
Not suitable for: R-702, R-717 and R-744
-
ATEX classification: II 3 G Ex ic IIA T2 Gc
-
Connectivity: Wireless Job Link connection
-
Radio frequency: 2.4 GHz
-
Wireless range: Up to 305 meters in line of sight
-
Detection signaling: Flashing LED, LCD bar graph, numerical LCD display, audible signal and Job Link app
-
Recalibration: Automatic or manual
-
Battery type: 4 replaceable AA lithium iron disulfide batteries
-
Recommended batteries for ATEX compliance: 4 × Energizer L91 AA
-
Battery voltage: 1.5 V DC nominal
-
Battery capacity: 3500 mAh
-
Battery life : Approximately 60 hours with normal use
-
Automatic shutdown: After 10 minutes without detection or operation
-
Operating temperature: -20 °C to +50 °C
-
Operating humidity : Less than 95% RH, non-condensing
-
Storage temperature: -20 °C to +60 °C
-
Storage humidity : Less than 95% RH, non-condensing
-
Protection class: IP54
-
Dimensions (L × W × H): 98 × 279 × 320 mm, external dimensions according to Linum
-
Device weight : 442 g including batteries according to the manufacturer
-
Weight according to order details: 1.45 kg
-
Package contents : DRX3 leak detector , RXA3 heated diode sensor , 4 ATEX-compliant AA batteries and carrying case
-
EAN: 5414618109812
-
SKU: 10420990001
-
-
Reviews (0)
The Fieldpiece Instruments FPI-8111-000 , model DRX3, is an ATEX-rated refrigerant leak detector with a heated diode sensor. The device has been developed for detecting refrigerant leaks and is designed for use with A1, A2L, and A3 refrigerants.
Sensitive detection of coolant leaks
The detector has a stated sensitivity of 1 gram per year. Thanks to the heated diode sensor, leaks of suitable coolants can be detected. The sensitivity is adjustable to high, medium, and low. The detector supports automatic and manual recalibration.
Job Link connectivity
The FPI-8111-000 features a Job Link connection that allows measurement data to be viewed. This supports the user in performing and assessing leak detection work.
Robust housing
The compact, robust housing has protection class IP54. The ATEX classification makes this model suitable for applications where the relevant explosion-proof classification is required. Always check whether the classification matches the specific working environment and the applicable safety regulations.
With its heated diode sensor, adjustable sensitivity, and wireless connectivity, the FPI-8111-000 is a practical solution for refrigeration technicians who want to detect refrigerant leaks in installations with suitable A1, A2L, and A3 refrigerants.
The product description is based on the product information from Linum Europe and the additional specifications from the manufacturer.
Specifications
-
Product type: Refrigerant leak detector
-
Type number: FPI-8111-000
-
Model type: DRX3
-
Brand: Fieldpiece Instruments
-
Sensor type: Heated diode
-
Sensor lifespan: 300 hours under normal use
-
Sensitivity levels: High, medium , and low
-
Detection sensitivity: 1 g/year at rest; 3 g/year in motion
-
Detectable refrigerants: HC, HFC, HCFC, CFC, HFO, mixtures and H₂/N₂ tracer gas
-
Suitable refrigerant classes: A1, A2L and A3
-
Not suitable for: R-702, R-717 and R-744
-
ATEX classification: II 3 G Ex ic IIA T2 Gc
-
Connectivity: Wireless Job Link connection
-
Radio frequency: 2.4 GHz
-
Wireless range: Up to 305 meters in line of sight
-
Detection signaling: Flashing LED, LCD bar graph, numerical LCD display, audible signal and Job Link app
-
Recalibration: Automatic or manual
-
Battery type: 4 replaceable AA lithium iron disulfide batteries
-
Recommended batteries for ATEX compliance: 4 × Energizer L91 AA
-
Battery voltage: 1.5 V DC nominal
-
Battery capacity: 3500 mAh
-
Battery life : Approximately 60 hours with normal use
-
Automatic shutdown: After 10 minutes without detection or operation
-
Operating temperature: -20 °C to +50 °C
-
Operating humidity : Less than 95% RH, non-condensing
-
Storage temperature: -20 °C to +60 °C
-
Storage humidity : Less than 95% RH, non-condensing
-
Protection class: IP54
-
Dimensions (L × W × H): 98 × 279 × 320 mm, external dimensions according to Linum
-
Device weight : 442 g including batteries according to the manufacturer
-
Weight according to order details: 1.45 kg
-
Package contents : DRX3 leak detector , RXA3 heated diode sensor , 4 ATEX-compliant AA batteries and carrying case
-
EAN: 5414618109812
-